T2P – Bipolar capillary thermostat
Bipolar capillary thermostat DPST and DPDT for temperature control.
The thermostat automatically opens the main contacts when the bulb probe reaches the set temperature value; subsequently when the temperature drops by the differential value it closes the contacts again. The controlled temperature is thus maintained within a minimum fluctuation.
Alternatively, the version that opens the two main contacts at two different temperatures is available, both adjustable via the thermostat knob, or in the fixed calibration version
Possible calibration ranges: starting from 0°C up to + 355°C
Main applications
Washing machines, domestic and professional electric ovens, professional coffee machines, electric and gas boilers, high-pressure washers, small household appliances, dryers and any other application where temperature regulation via bipolar control or two different temperatures is required.
DPST and DPDT bipolar capillary thermostat for temperature control.
The thermostat automatically opens the main contacts when the bulb probe reaches the set temperature value; subsequently when the temperature drops by the differential value it closes the contacts again. The controlled temperature is thus maintained within a minimum fluctuation.
Alternatively, the version that opens the two main contacts at two different temperatures is available, both adjustable via the thermostat knob, or in the fixed calibration version
Possible calibration ranges: starting from 0°C up to + 355°C
Main applications
Washing machines, domestic and professional electric ovens, professional coffee machines, electric and gas boilers, high-pressure washers, small household appliances, dryers and any other application where temperature regulation via bipolar control or two different temperatures is required.
Duration: | 100,000 cycles | Working range (min-max): | 0-150 °C (T85) / 50-355 (T150)°C |
Contact range: | 20(4)A-4(1)A/250 VAC 16(4)A-4(1)A/400 VAC | Capillary: | Ø 1.4 (Copper) Ø 1 (Stainless steel) |
Operation type: | 2 C | Capillary length: | Min 250 – max 2000 (2500) |
Max body temp: | T85 (Plastic body) T150(Ceramic body) | Sensor (bulb): | Bulb: Stainless steel Ø3; Ø4; Ø6 Copper:Ø5; Ø6; Ø6.5; Ø8 Cup: Stainless steel: Ø15; Ø23.5 Copper: Ø9.5 |
Protection class: | Class I., / IP 00 | Max temp. bulb: | +15% of the max temperature value |
Device operation: | Normal | Surface protection: | Blue passivated galvanizing |
Fire resistant: | D | Post Length: | 16-50 mm |
Isolation: | ≥ 175 MOhm | Connections: | Faston, A 6.3×0.8 |