T3P – Three-pole capillary thermostat
Three-pole capillary thermostat TPST and TPDT for temperature control.
The thermostat automatically opens the main contacts when the bulb probe reaches the set temperature value; subsequently when the temperature drops by the differential value it closes the contacts again. The controlled temperature is thus maintained within a minimum fluctuation.
Alternatively, the version that opens the three main contacts at three different temperatures is available, all adjustable via the thermostat shaft, or they can be in the fixed calibration version
Possible calibration ranges: starting from 0°C up to + 355°C
Main applications
Professional electric ovens, professional coffee machines, electric and gas boilers, saunas, industrial air heaters, dryers and any other application where temperature regulation via three-phase control or three different temperatures is required.
Three-pole capillary thermostat TPST and TPDT for temperature control.
The thermostat automatically opens the main contacts when the bulb probe reaches the set temperature value; subsequently when the temperature drops by the differential value it closes the contacts again. The controlled temperature is thus maintained within a minimum fluctuation.
Alternatively, the version that opens the three main contacts at three different temperatures is available, all adjustable via the thermostat shaft, or they can be in the fixed calibration version
Possible calibration ranges: starting from 0°C up to + 355°C
Main applications
Professional electric ovens, professional coffee machines, electric and gas boilers, saunas, industrial air heaters, dryers and any other application where temperature regulation via three-phase control or three different temperatures is required.
Duration: | 100,000 cycles | Working range (min-max): | 0-150 °C (T85) / 50-355 (T150)°C |
Contact range: | 20(4)A-4(1)A/250 VAC 16(4)A-4(1)A/400 VAC | Capillary: | Ø 1.4 (Copper) Ø 1 (Stainless steel) |
Operation type: | 2 C | Capillary length: | Min 250 – max 2000 (2500) |
Max body temp: | T85 (Plastic body) T150(Ceramic body) | Sensor (bulb): | Bulb: Stainless steel Ø3; Ø4; Ø6 Copper:Ø5; Ø6; Ø6.5; Ø8 Cup: Stainless steel: Ø15; Ø23.5 Copper: Ø9.5 |
Protection class: | Class I., / IP 00 | Max temp. bulb: | +15% of the max temperature value |
Device operation: | Normal | Surface protection: | Blue passivated galvanizing |
Fire resistant: | D | Post Length: | 16-50 mm |
Isolation: | ≥ 175 MOhm | Connections: | Faston, A 6.3×0.8 |