T4PM – Three-pole TPST or four-pole FPST capillary limiting thermostat
Three-pole TPST or four-pole FPST capillary limiting thermostat with manual reset and intrinsic safety (opens the contacts in the event of breakage or loss of the capillary sensor or bulb).The thermostat automatically opens the main contacts when the sensor reaches the set temperature value, in order to avoid dangerous overheating; subsequently, once the faulty thermoregulation system has been repaired and the temperature has dropped, the thermostat can be reset manually. Possible calibration ranges: from +77°C up to +270°C Main applications Professional coffee machines, electric storage water heaters, small appliances, saunas, air heaters, centralized boilers and any other application where a maximum temperature safety thermostat with manual reset with three-pole or four-pole opening and intrinsic safety is required.
Three-pole TPST or four-pole FPST capillary limiting thermostat with manual reset and intrinsic safety (opens the contacts in the event of breakage or loss of the capillary sensor or bulb).
The thermostat automatically opens the main contacts when the sensor reaches the set temperature value, in order to avoid dangerous overheating; subsequently, once the faulty thermoregulation system has been repaired and the temperature has dropped, the thermostat can be reset manually.
Possible calibration ranges: from +77°C up to +270°C
Main applications
Professional coffee machines, electric storage water heaters, small appliances, saunas, air heaters, centralized boilers and any other application where a maximum temperature safety thermostat with manual reset with three-pole or four-pole opening and intrinsic safety is required.
Life cycle: | 1,000 cycles | Working range (min-max): | 0-120 °C (T85) / 120-200 °C (T150) / 200-355°C (T150) |
Contact range: | 20(4)A-4(1)A/250 VAC 16(4)A-4(1)A/400 VAC | Capillary: | Ø 2 (copper) Ø 1 (steel) |
Operation type: | BSB:2AGKLM | Capillary length: | Min 500 – max 2000 (2500) |
Max temp. around the body: | T85 (Plastic body) T150(Ceramic body) | Bulb: | Copper: Ø 6; Ø 8 Steel: Ø 3; Ø 4; Ø 6 |
Protection class: | Class 0., / IP 00 | Max temp. bulb: | +15% of the max working value |
Device operation: | Normal | Surface protection: | Blue passivation |
Fire and heat resistance: | D | Connections: | Faston, A 6.3×0.8 |
Isolation: | ≥ 175 MOhm |